Description
The MLX90640BAB Infrared Thermal Imaging Sensor with Metal Housing and Modbus Protocol is an industrial-grade, 32×24 pixel thermal array module designed for direct integration into RS485/Modbus networks. It combines the Melexis MLX90640BAB far-infrared sensor with an M12 metal tube enclosure and onboard Modbus communication circuitry, eliminating the need for a separate microcontroller in industrial deployments .
The MLX90640BAB sensor uses the 55° × 35° standard field of view, making it suitable for longer-distance measurement compared to the wide-angle BAA variant . It measures object temperatures from -40°C to +300°C with a module-level accuracy of approximately ±2°C, and operates in ambient temperatures from -20°C to +85°C . The sensor’s NETD of 0.1K RMS at 1Hz provides good thermal sensitivity for detecting small temperature differences .
The metal housing provides mechanical protection and electromagnetic shielding, making the module suitable for harsh industrial environments where a bare PCB would be vulnerable to dust, moisture, and electrical noise. The Modbus protocol output allows direct connection to PLCs, industrial controllers, and SCADA systems via RS485, with the module acting as a slave device on the bus.
Critical limitations: The ±2°C module accuracy is inferior to the bare chip’s ±1°C specification and is not suitable for medical-grade screening. The 32×24 resolution is coarse—adequate for hot-spot detection and presence sensing, but not for detailed thermal analysis. The 55° × 35° FOV means the module must be aimed more precisely than the wide-angle BAA variant, and it cannot see through glass or most plastics. Modbus configuration (baud rate, slave address, register mapping) must be set correctly before the module will respond on the bus—consult the supplier’s protocol documentation.
Features
-
Industrial Modbus/RS485 Interface: Direct integration with PLCs and SCADA systems without a host microcontroller .
-
M12 Metal Tube Housing: Mechanical protection and EMI shielding for harsh environments .
-
32×24 Pixel Thermal Array: Grid temperature measurement for hot-spot detection and presence sensing .
-
55° × 35° Standard FOV (BAB): Narrower field of view for longer-distance targeting .
-
Wide Object Temperature Range (-40°C to +300°C): Suitable for industrial equipment monitoring .
-
Good Thermal Sensitivity (NETD 0.1K @ 1Hz): Detects small temperature differences .
-
No Frequent Recalibration Required: Unlike microbolometers, maintains accuracy without periodic user calibration .
-
Compact M12 Form Factor: Standard industrial mounting thread for easy installation.
Technical Specifications
| Parameter | Specification (GY-MODBUS-90640BAB-12) |
|---|---|
| Sensor | Melexis MLX90640BAB |
| Pixel Array | 32 × 24 (768 pixels) |
| Field of View (BAB) | 55° × 35° |
| Object Temperature Range | -40°C to +300°C |
| Measurement Accuracy (Module) | ±2°C |
| Operating Temperature | -20°C to +85°C |
| Interface | Modbus (RS485) |
| Housing | M12 metal tube |
| Supply Voltage | 3–5V (module logic) |
| Response Frequency | 8Hz |










Reviews
There are no reviews yet.