Description
The MH-Z19C is a small, low-cost NDIR (non-dispersive infrared) CO2 sensor module designed for indoor air quality monitoring, HVAC ventilation control, air purifiers, and smart home devices . It detects CO2 concentration by measuring infrared absorption at carbon dioxide’s characteristic wavelength, offering good selectivity and long life without oxygen dependence.
The sensor provides UART (TTL 3.3V, 5V-compatible) and PWM outputs, making it directly compatible with Arduino, ESP32, and Raspberry Pi . It operates from a tightly regulated 5.0V ± 0.1V supply with average current below 40mA (peak 125mA) and includes built-in temperature compensation . The detection chamber is gold-plated for water-proofing and anti-corrosion, and the sensor is rated for >10 years of life per Winsen’s current specification .
Compared to the MH-Z19B it replaces, the MH-Z19C has a single gas intake window (vs. two), a 1-second sampling period (vs. 5 seconds), and adds an analog output (DAC) option . These improvements make it more responsive and versatile for new designs.
Critical limitations: The MH-Z19C has Automatic Baseline Correction (ABC) enabled by default, which assumes the sensor sees fresh outdoor air (~400ppm) at least once every 24 hours. In continuously occupied rooms, greenhouses, or refrigerators where CO2 never drops to baseline, ABC causes inflated, drifting readings . Disable ABC and perform manual zero-point calibration for these environments. The sensor cannot be used outdoors per Winsen’s intended applications . The UART runs at 3.3V logic—when connecting to a 5V Arduino, the Arduino’s TX line needs a voltage divider (e.g., 1kΩ/2kΩ) to protect the sensor’s RX pin .
Features
-
NDIR Infrared Detection: Selective CO2 measurement with no oxygen dependence and long life (>10 years) .
-
UART and PWM Outputs: Dual interface options; UART is 3.3V TTL compatible with 5V logic .
-
Built-in Temperature Compensation: Stable readings across the operating range .
-
Gold-Plated Chamber: Water-proof and anti-corrosion construction .
-
Multiple Detection Ranges: 400–2000ppm, 400–5000ppm, and 400–10000ppm options .
-
Faster Sampling (1s): Improved responsiveness vs. the MH-Z19B’s 5s period .
-
Low Power Consumption: <40mA average, 125mA peak .
-
Direct MH-Z19B Replacement: Same size and pinout, with better consistency .
Technical Specifications
| Parameter | Specification (MH-Z19C) |
|---|---|
| Detection Principle | Non-dispersive infrared (NDIR) |
| Detection Range | 400–5000ppm (standard); 400–10000ppm optional |
| Accuracy | ±(50ppm + 5% of reading) |
| Operating Voltage | 5.0V ± 0.1V DC |
| Average Current | <40mA @ 5V |
| Peak Current | 125mA @ 5V |
| Output Interface | UART (TTL 3.3V), PWM |
| Preheat Time | 1 minute (product page) / 2.5 minutes (datasheet) |
| Response Time | T90 < 120s |
| Operating Temperature | -10°C to +50°C |
| Operating Humidity | 0–95% RH (no condensation) |
| Dimensions | 32.9 × 19.7 × 8.6mm |
| Lifespan | >10 years |















Reviews
There are no reviews yet.