MCU-8118 Multi-Gas Sensor Module – CO2, VOCs, Temperature & Humidity Detection (CCS811 + HDC1080 Chipset)

$9.02

SKU: FA3151-2 Category:

Description

The MCU-8118 is a multi-parameter air quality monitoring module combining the CCS811 gas sensor and the HDC1080 humidity/temperature sensor. The CCS811 detects a broad range of volatile organic compounds and internally calculates eCO2 (400–8000ppm) and TVOC (0–1100ppb) values, while the HDC1080 provides ±2% RH and ±0.2°C typical accuracy for environmental compensation .

Both sensors share the same I²C bus, with the CCS811 at address 0x5A (configurable to 0x5B) and the HDC1080 at its fixed address. The module operates from 3.3V to 5.5V and is compatible with Arduino, ESP32, and other 3.3V/5V systems . The CCS811 supports multiple measurement modes (1s, 10s, 60s, 250ms) and includes a configurable interrupt pin for threshold alerts.

Critical limitations: The CCS811 requires 20 minutes of warm-up after each power cycle and a 48-hour initial burn-in for stable readings. It uses I²C clock stretching, which is not natively supported by Raspberry Pi and can cause communication failures on some hosts . The eCO2 output is a relative air quality indicator, not a precise CO2 concentration.

Features

  • Dual-Sensor Combo: CCS811 (eCO2/TVOC) + HDC1080 (temp/humidity) on one board .

  • Environmental Compensation: HDC1080 data can be fed to CCS811 to improve gas readings .

  • Wide Supply Compatibility: 3.3V–5.5V operation .

  • Multiple Measurement Modes: 1s, 10s, 60s, 250ms, and sleep.

  • Configurable Interrupt: Threshold-based alert for eCO2/TVOC.

  • Compact Size: Approximately 15×21mm .

  • I²C Interface: Shared bus for both sensors.

  • Arduino Library Support: DFRobot CCS811 and ClosedCube HDC1080 libraries available .

Technical Specifications

Parameter CCS811 (Gas) HDC1080 (Temp/Humidity)
Measurement eCO2: 400–8000ppm; TVOC: 0–1100ppb Temp: -40 to +125°C; RH: 0–100%
Accuracy ±(50ppm + 5%) typical for eCO2 ±0.2°C, ±2% RH typical
Supply Voltage 3.3V–5.5V 2.7V–5.5V
I²C Address 0x5A / 0x5B Fixed address (consult datasheet)
Warm-up 20 min per power cycle Factory calibrated, fast response
Sleep Current 10µA (CCS811) 100nA
Module Size Approx. 15×21mm —

Additional information

Weight 0.002 kg
Measurement

Temp: -40 to +125°C; RH: 0–100%

Accuracy

±0.2°C, ±2% RH typical

Supply Voltage

2.7V–5.5V

I²C Address

Fixed address (consult datasheet)

Warm-up

Factory calibrated, fast response

Sleep Current

100nA

Reviews

There are no reviews yet.

Be the first to review “MCU-8118 Multi-Gas Sensor Module – CO2, VOCs, Temperature & Humidity Detection (CCS811 + HDC1080 Chipset)”