Description
The GY-906 MLX90614ESF-DCI is a non-contact infrared temperature sensor module built around the Melexis MLX90614ESF-DCI, the narrow-field-of-view (5°) variant of the MLX90614 family. Unlike the wide-angle BAA (90°) and BCC (35°) versions, the DCI’s 5° cone creates a small measurement spot at distance—at 50cm, the spot diameter is approximately 4.3cm . This makes it suitable for targeted measurement of small or distant objects where a wide FOV would average in background temperature.
The module outputs object and ambient temperatures via I²C (SMBus compatible) at address 0x5A. The GY-906 breakout board typically includes a 3–5V input with an onboard low-dropout regulator, making it compatible with both 3.3V and 5V microcontrollers . The sensor is factory-calibrated and offers 0.02°C measurement resolution .
The DCI variant is often marketed as a medical-grade sensor for body temperature screening, offering ±0.2°C accuracy in the human body temperature range, with ±0.5°C accuracy over the broader room-temperature range . It is also used for industrial long-distance measurement and high-temperature target sensing where the narrow FOV helps isolate the target from background radiation.
Critical limitations: The 5° FOV requires precise aiming—if the target does not fully cover the spot, background temperature skews the reading . The sensor cannot measure through glass, and shiny metals (low emissivity) require compensation. The maximum object temperature for the DCI variant may be lower than the standard MLX90614 (approximately 273–280°C vs. 380°C) . The module is not a certified medical device despite the “medical accuracy” labeling.
Features
-
5° Narrow Field of View (DCI): Enables targeted measurement of small or distant objects; spot diameter ≈ 0.087 × distance .
-
Dual Temperature Output: Object temperature and ambient temperature via I²C.
-
Medical-Grade Accuracy in Body Range: ±0.2°C in the human body temperature window (verify with supplier) .
-
3V/5V Module Compatibility: Onboard regulator on GY-906 breakout allows 3–5V supply .
-
I²C Interface (0x5A): Standard two-wire communication.
-
High Resolution: 0.02°C measurement resolution .
-
Compact Breakout: Small PCB with 10kΩ I²C pull-ups .
-
Widely Supported: Adafruit and SparkFun libraries available.
Technical Specifications
| Parameter | Specification (MLX90614ESF-DCI) |
|---|---|
| Sensor | Melexis MLX90614ESF-DCI |
| Field of View | 5° |
| Object Temperature Range | -70°C to +380°C (verify DCI limit: ~273–280°C per sources) |
| Ambient Temperature Range | -40°C to +85°C |
| Accuracy (Body Range) | ±0.2°C (medical variant, limited range) |
| Accuracy (Broad Range) | ±0.5°C (typical) |
| Resolution | 0.02°C |
| Interface | I²C / SMBus (address 0x5A) |
| Supply Voltage (Module) | 3–5V (onboard regulator) |
| Measurement Distance | Up to ~1m (per supplier, accuracy degrades with distance) |