SCT-013-100 Split Core Current Transformer | 100A/1V Output | 1% Accuracy | 1m Cable Length | Non-Invasive AC Sensor

$2.97

SKU: FA3080-7 Category:

Description

The SCT-013 series is a split-core AC current transformer designed for non-invasive current measurement in energy monitoring, load diagnostics, and equipment protection. The clamp-on design allows installation around an existing insulated conductor without cutting or disconnecting the wire, making it suitable for retrofitting into live electrical installations. The 100A voltage-output variant includes an internal sampling resistor, delivering a direct 0–1V AC output proportional to the primary current—no external burden resistor is required for basic operation .

This model is rated for 100A AC (RMS) input and is commonly used for monitoring whole-building consumption, large AC motors, and industrial equipment. The 1-meter cable terminates in a standard 3.5mm audio plug . The sensor is suitable for individual makers building Arduino-based energy monitors and for business purchasers seeking a cost-effective, non-invasive current sensing solution for commercial and light industrial applications.

Accuracy note: Several distributor listings specify ±1% accuracy with linearity ≤0.2% for the SCT-013 series . However, the manufacturer’s general datasheet specifies non-linearity of ±3% (10%–120% of rated input) . The ±1% figure may apply to specific calibrated conditions or branded units. For critical applications, calibrate against a known reference load.

Features

  • Non-Invasive Split-Core Design: Clamps around an existing conductor without disconnecting the circuit, enabling safe retrofitting into live installations .

  • Voltage Output with Internal Sampling Resistor: Provides a direct 0–1V AC output ready for ADC connection; no external burden resistor required .

  • 100A Measurement Range: Suitable for whole-building monitoring, large motors, and industrial equipment.

  • 13mm × 13mm Opening: Accommodates typical domestic and commercial wiring .

  • 1-Meter Cable with 3.5mm Plug: Standardized connector simplifies connection to energy monitoring boards .

  • Ferrite Core Construction: Provides stable magnetic coupling and consistent ratio across the measurement range .

  • Safety Lock Buckle: Secure closure helps maintain core alignment and measurement accuracy .

  • UL94-V0 Flame Retardant Housing: Meets recognized fire safety standards .

Technical Specifications

Parameter Specification
Model (as titled) SCT-013-100 (verify actual output variant)
Primary Current Range 0–100A AC (RMS)
Output Signal (voltage variant) 0–1V AC (internal sampling resistor)
Output Signal (standard -100) 0–50mA (external burden required)
Turns Ratio 1:2000 (for 100A/50mA current output)
Opening Size 13mm × 13mm
Cable Length 1 meter
Connector 3.5mm audio plug
Accuracy (distributor spec) ±1%, linearity ≤0.2%
Non-linearity (manufacturer spec) ±3% (10%–120% of rated input)
Operating Temperature -25°C to +70°C
Dielectric Strength 6000V AC/1min (housing to output) 

Additional information

Model (as titled)

SCT-013-100 (verify actual output variant)

Primary Current Range

0–100A AC (RMS)

Output Signal (voltage variant)

0–1V AC (internal sampling resistor)

Output Signal (standard -100)

0–50mA (external burden required)

Turns Ratio

1:2000 (for 100A/50mA current output)

Opening Size

13mm × 13mm

Cable Length

1 meter

Connector

3.5mm audio plug

Accuracy (distributor spec)

±1%, linearity ≤0.2%

Non-linearity (manufacturer spec)

±3% (10%–120% of rated input)

Operating Temperature

-25°C to +70°C

Dielectric Strength

6000V AC/1min (housing to output)

Reviews

There are no reviews yet.

Be the first to review “SCT-013-100 Split Core Current Transformer | 100A/1V Output | 1% Accuracy | 1m Cable Length | Non-Invasive AC Sensor”