TS-300B High-Precision Turbidity Sensor Module – Water Quality Detection Sensor

$3.01

SKU: FA3152-2 Category:

Description

The TS-300B is an optical turbidity sensor module designed to measure water clarity by detecting suspended particles. It consists of a probe containing an infrared LED (peak emission 940nm) and a phototransistor (peak sensitivity 880nm), plus a driver board that converts the optical signal into analog and digital outputs .

The sensor operates on the principle of light transmission: the infrared LED emits light through the water, and the phototransistor measures the transmitted light intensity. Cleaner water transmits more light (higher voltage output), while turbid water with suspended particles scatters and absorbs light (lower voltage output) . The analog output range is 0–4.5V .

The module includes an onboard potentiometer for adjusting the digital output threshold and a slide switch to select between analog (A) and digital (D) output modes. It operates from 5V DC with a maximum current of approximately 40mA .

Critical limitations: The sensor provides relative turbidity, not calibrated NTU values. The detection range is listed as 0–1000±30 NTU by one supplier , but actual usable range depends on calibration. Direct sunlight or strong ambient light affects readings and should be avoided . The sensor head housing should be kept clean to avoid measurement errors from contamination .

Features

  • Optical Turbidity Sensing: Infrared LED (940nm) and phototransistor (880nm) measure light transmission through water .

  • Dual Outputs: Analog voltage (0–4.5V) and digital HIGH/LOW threshold .

  • Adjustable Digital Threshold: Onboard potentiometer sets the digital trigger level .

  • Selectable Output Mode: Slide switch selects analog (A) or digital (D) .

  • Fast Response: <500ms response time .

  • Wide Operating Temperature: -20°C to +90°C .

  • Arduino Compatible: Simple 3-pin connection (VCC, GND, Signal) .

Technical Specifications

Parameter Specification
Operating Voltage 5V DC
Operating Current 40mA max
Analog Output 0–4.5V; decreases as turbidity increases
Digital Output HIGH/LOW, threshold adjustable via potentiometer
Detection Range 0–1000±30 NTU (per one supplier)
Response Time <500ms
Operating Temperature -20°C to +90°C
Probe Waterproofing Tip only; top and cable connection are NOT waterproof 

Additional information

Weight 0.012 kg
Operating Voltage

5V DC

Operating Current

40mA max

Analog Output

0–4.5V; decreases as turbidity increases

Digital Output

HIGH/LOW, threshold adjustable via potentiometer

Detection Range

0–1000±30 NTU (per one supplier)

Response Time

<500ms

Operating Temperature

-20°C to +90°C

Probe Waterproofing

Tip only; top and cable connection are NOT waterproof