Description
The TS-300B is a low-cost optical turbidity sensor module designed for water clarity detection in washing machines, dishwashers, industrial controls, and DIY water quality projects. It consists of a probe containing an infrared LED and phototransistor, and a driver board that converts the optical signal into both analog and digital outputs .
The sensor operates on the principle of light transmission: the infrared LED emits light through the water, and the phototransistor measures the transmitted light intensity. Cleaner water transmits more light (higher voltage output), while turbid water with suspended particles scatters and absorbs light (lower voltage output) . The analog output range is approximately 0–4.5V .
The module includes an onboard potentiometer for adjusting the digital output threshold and a slide switch to select between Analog (A) and Digital (D) output modes. When the switch is set to A, the signal pin outputs a continuous voltage for ADC reading .
Critical limitations: The sensor provides relative turbidity, not calibrated NTU values. Academic testing found accuracy errors of ±5% to ±10% depending on calibration and conditions . The probe must be immersed only up to the waterline—the cable connection is not sealed . Direct sunlight or strong ambient light affects readings and should be avoided .
Features
-
Optical Turbidity Sensing: Infrared LED (940nm) and phototransistor measure light transmission through water .
-
Analog Output Mode (A): Continuous 0–4.5V output for ADC reading .
-
Adjustable Digital Threshold: Onboard potentiometer sets the digital trigger level .
-
Selectable Output Mode: Slide switch chooses Analog (A) or Digital (D) .
-
Low Cost: Inexpensive solution for relative water clarity monitoring.
-
Wide Operating Temperature: -20°C to +90°C per retailer listings .
-
Arduino Compatible: Simple 3-pin connection (VCC, GND, Signal) .
Technical Specifications
| Parameter | Specification |
|---|---|
| Operating Voltage | 5V DC |
| Operating Current | ~11mA (some list 40mA max) |
| Analog Output | 0–4.5V; decreases as turbidity increases |
| Digital Output | HIGH/LOW, threshold adjustable via potentiometer |
| Detection Range | 0–3.5% (0–4550 NTU per one supplier) |
| Operating Temperature | -20°C to +90°C (varies by source) |
| Response Time | <500ms |
| Probe Waterproofing | Tip only; top and cable connection are NOT waterproof |