Hall water flow sensor DN20 G3/4 copper flow meter YF-B6 DC5~18V [water inlet outer teeth 6 points water outlet outer teeth 6 points]

$3.76

SKU: FA3105-5 Category:

Description

The YF-B6 is a Hall-effect turbine water flow sensor featuring a copper/brass housing with G3/4″ (DN20) double male threaded connections on both inlet and outlet. This larger-bore sensor is designed for accurate flow measurement in water dispensers, coffee machines, and fully automatic gas water heaters, where the 1/2″ (DN15) sensors cannot accommodate the required flow rate .

The sensor operates on a turbine principle: water flowing through the body spins a magnetic rotor, and an integrated Hall-effect sensor detects the rotation, outputting a digital pulse train proportional to flow rate . The rated flow range is 1–30 L/min, with a frequency relationship of F = 6.6 × Q (Hz, where Q is flow rate in L/min). This corresponds to approximately 396 pulses per liter (each pulse ≈ 2.53 mL) when correctly interpreted as 6.6 pulses per second per L/min .

The sensor operates from DC 3.5V to 24V according to MIKROE, while Seeed Studio specifies DC 5V to 15V (minimum 4.5V) . The maximum current draw is 15mA at 5V, and the output is an NPN pulse signal with high level >4.7V and low level <0.5V at 5V supply . The copper body (H57 copper + POM) withstands up to 1.75 MPa pressure and handles liquid temperatures up to 120°C, making it suitable for hot water applications .

Critical limitations: This is a low-cost, non-certified sensor for hobbyist, educational, and light commercial use. For 3.3V microcontrollers (ESP32, ESP8266), the pulse output high level (>4.7V at 5V supply) requires a logic level shifter or voltage divider to protect GPIO pins. A filter screen should be installed upstream to prevent debris from jamming the turbine . Note that the pulse factor is a common source of confusion—Seeed Studio’s F = 6.6 × Q formula refers to pulses per second, not pulses per liter .

Features

  • Copper/Brass Housing with Double Male Threads: Both inlet and outlet are G3/4″ (DN20) male threads; longer life and better sealing than plastic bodies .

  • Hall-Effect Pulse Output: Digital square wave proportional to flow rate, readable by any microcontroller with an interrupt-capable GPIO .

  • ~396 Pulses per Liter: Good resolution for volume tracking; each pulse ≈ 2.53 mL when correctly calibrated .

  • Flow Range 1–30 L/min: Suitable for water dispensers, coffee machines, and gas water heaters .

  • Wide Voltage Range (DC 3.5–24V): Flexible compatibility with 5V and higher supply systems .

  • High Pressure Resistance (≤1.75 MPa): Suitable for pressurized water systems .

  • Hot Water Compatible: Liquid temperature up to 120°C .

  • RoHS Compliant: Meets environmental compliance requirements .

Technical Specifications

Parameter Specification
Model YF-B6
Connection Size G3/4″ (DN20), double male thread
Body Material H57 Copper + POM
Operating Voltage DC 3.5V – 24V ; DC 5V – 15V per Seeed
Max Current Draw 15mA @ 5V
Output Signal NPN pulse; high >4.7V, low <0.5V (at 5V input)
Flow Rate Range 1 – 30 L/min
Frequency Formula F = 6.6 × Q (Hz, Q in L/min)
Pulses per Liter ~396 pulses/L (≈2.53 mL per pulse)
Accuracy ±3% (1–25 L/min)
Max Water Pressure ≤1.75 MPa
Operating Temperature 0 – 80°C
Liquid Temperature ≤120°C
Dimensions Approx. 60mm length, 11mm thread
Weight Approx. 152g

Additional information

Model

YF-B6

Connection Size

G3/4" (DN20), double male thread

Body Material

H57 Copper + POM

Operating Voltage

DC 3.5V – 24V ; DC 5V – 15V per Seeed

Max Current Draw

15mA @ 5V

Output Signal

NPN pulse; high >4.7V, low <0.5V (at 5V input)

Flow Rate Range

1 – 30 L/min

Frequency Formula

F = 6.6 × Q (Hz, Q in L/min)

Pulses per Liter

~396 pulses/L (≈2.53 mL per pulse)

Accuracy

±3% (1–25 L/min)

Max Water Pressure

≤1.75 MPa

Operating Temperature

0 – 80°C

Liquid Temperature

≤120°C

Reviews

There are no reviews yet.

Be the first to review “Hall water flow sensor DN20 G3/4 copper flow meter YF-B6 DC5~18V [water inlet outer teeth 6 points water outlet outer teeth 6 points]”